Fire-Lite MRP-2002 Single and Dual Hazard Agent Release Control Panel, 6-Zone and 24V

$1,669.70

Product Overview

The MRP-2002 is a six-zone FACP for single and dual hazard agent releasing applications. The MRP-2002 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. The MRP-2002 is compatible with System Sensor's i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory 'freeze' signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the FireLite Device Compatibility Document for a complete listing of compatible devices.

Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The MRP-2002 supervises all wiring, AC voltage, battery charger and battery level.

Activation of a compatible smoke detector or any normallyopen fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panel's LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function.

The MRP-2002E offers the same features as the MRP-2002 but allows connection to 220/240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 110/ 120 VAC and 220/240 VAC versions of the panels.

Main Features
  • Listed to UL Standard 864, 9th edition.
  • FM Approved.
  • Designed for agent releasing standards NFPA 12, 12A, 12B, and 2001.
  • Meets International Building Code (IBC) seismic requirements.
  • Disable/Enable control per input zone and output zone.
  • Extensive transient protection.
  • Dual hazard operation.
  • Adjustable pre-discharge, discharge and waterflow delay timers.
  • Cross-zone (double-interlock) capability.
  • Six programmable Style B (Class B) IDCs (Initiating Device Circuit).
  • System Sensor i3 series detector compatible.
  • Four programmable Style Y (Class B) output circuits - (special application power).
  • Strobe synchronization:
    • System Sensor
    • Wheelock
    • Gentex
    • Faraday
    • Amseco
  • Three programmable Form-C relays.
  • 7.0 amps total 24 VDC output current.
  • Resettable and non-resettable output power.
  • Built-in Programmer.
  • ANN-BUS connector for communication with optional devices (up to 8 total of any of the following):
    • ANN-80 Remote LCD Annunciator
    • ANN-I/O LED Driver
    • ANN-S/PG Printer Modules
    • ANN-RLY Relay Module
    • ANN-LED Annunciator Module
  • 80-character LCD display (backlit).
  • Real-time clock/calendar with daylight savings time control.
  • History log with 256 event storage.
  • Piezo sounder for alarm, trouble and supervisory.
  • 24 volt operation.
  • Low AC voltage sense.
  • Outputs Programmable for:
    • Releasing Circuits or NACS
  • NACs programmable for:
    • Silence Inhibit
    • Auto-Silence
    • Strobe Synchronization
    • Selective Silence (horn-strobe mute)
General Information
Name: Fire-Lite MRP-2002 Single and Dual Hazard Agent Release Control Panel, 6-Zone and 24V, Honeywell International, Inc, Fire-Lite Alarms by Honeywell
Category: Fire-Lite Alarms by Honeywell, Fire, Fire Control Panels, Fire Alarm Control Panels
UPC Code: 783008109103
Country of Origin: United States. Country of origin is subject to change.


You may also like

Recently viewed