Set up Silarius access control and entry devices
Wire a reader, keypad or intercom and add users.
This lesson covers Silarius face terminals (SIL-FRTEMP and SIL-ACCESSTEMP), their floor stands, and the tripod turnstile (SIL-TURNSTILE3ARMSS). Lock wiring and mains power should be done by a qualified installer or electrician.
What you need
- A power supply rated for the device (check the label)
- A network cable
- An electric door lock (for door control), installed by a pro
Lock and mains wiring must follow fire and building codes. Doors on escape routes must open when the power fails. Use a qualified installer.
Step by step
- Mount the terminal
Mount it about 4.6 to 5 ft (1.4 to 1.5 m) high, measured to the camera. Keep it out of direct sun and away from a bright window behind people.
- Wire the door lock
Magnetic lock (unlocks when power is cut): lock + to COM, NC to the lock power. Door strike (locks when power is cut): use NO. Connect the exit button and door contact to their inputs. Put a diode across DC locks.
- Turnstile
Bolt it to concrete. Mains power by a licensed electrician. Connect its open signal (a dry contact) to the terminal relay or controller.
- Open the admin menu
Power on. Long-press the screen (or press Menu). The first time, create the admin password.
- Network
Admin → Network: DHCP, or a fixed address, mask and gateway.
- Add people
Admin → User → Add: name, ID, and a face photo (good light, look at the camera). Add a card or PIN if you want. Set the times they may enter.
- Door settings
Admin → Access / Door: how long the lock opens (example 3 seconds), the door sensor, and the Wiegand output format for an access controller.
- Temperature check (models with it)
Admin → Temperature: set the alarm level and whether to refuse entry.
- Attendance records
Export records to a USB stick (Admin → Records / Data → Export), for example for payroll.
- Test it
Test with an enrolled person before you leave the site.
Quick setup facts
- Face terminals (SIL-FRTEMP, SIL-ACCESSTEMP): set up on the device screen. Long-press the screen (or Menu) for the admin menu. Create the admin password the first time.
- Network: RJ45 10/100. DHCP or a fixed address in Admin → Network.
- Door wiring: lock relay (NO / COM / NC), exit button, door contact, and Wiegand 26/34 out to an access controller.
- Turnstile (SIL-TURNSTILE3ARMSS): opens from a dry contact / relay signal (terminal, card reader or button).
- Power: 12V DC adapter (terminals). Turnstile: mains power by an electrician.
Words to know
- Access control: Lets only the right people through a door or gate.
- Relay: An electric switch inside the device that unlocks the door lock.
- IP address: The device's address on your network, like a house number (for example 192.168.1.88).
- Enrolment: Adding a person's face or card to the device.
What's in the box
- The device
- Power supply or cable set (as listed)
- Mounting hardware
- Quick start card
Care
- Clean the lens and screen with a soft, dry cloth.
- Back up users to a USB stick from time to time.
Common questions
Something is wrong
Still stuck? We'll do it with you, free.
Silarius customers can get free remote help: sign in, click one button, and a Silarius technician joins your computer.