Set up Silarius access control and entry devices

Wire a reader, keypad or intercom and add users.

3 min Intermediate

This lesson covers Silarius face terminals (SIL-FRTEMP and SIL-ACCESSTEMP), their floor stands, and the tripod turnstile (SIL-TURNSTILE3ARMSS). Lock wiring and mains power should be done by a qualified installer or electrician.

What you need

  • A power supply rated for the device (check the label)
  • A network cable
  • An electric door lock (for door control), installed by a pro

Lock and mains wiring must follow fire and building codes. Doors on escape routes must open when the power fails. Use a qualified installer.

Step by step

  1. Mount the terminal

    Mount it about 4.6 to 5 ft (1.4 to 1.5 m) high, measured to the camera. Keep it out of direct sun and away from a bright window behind people.

  2. Wire the door lock

    Magnetic lock (unlocks when power is cut): lock + to COM, NC to the lock power. Door strike (locks when power is cut): use NO. Connect the exit button and door contact to their inputs. Put a diode across DC locks.

  3. Turnstile

    Bolt it to concrete. Mains power by a licensed electrician. Connect its open signal (a dry contact) to the terminal relay or controller.

  4. Open the admin menu

    Power on. Long-press the screen (or press Menu). The first time, create the admin password.

  5. Network

    Admin → Network: DHCP, or a fixed address, mask and gateway.

  6. Add people

    Admin → User → Add: name, ID, and a face photo (good light, look at the camera). Add a card or PIN if you want. Set the times they may enter.

  7. Door settings

    Admin → Access / Door: how long the lock opens (example 3 seconds), the door sensor, and the Wiegand output format for an access controller.

  8. Temperature check (models with it)

    Admin → Temperature: set the alarm level and whether to refuse entry.

  9. Attendance records

    Export records to a USB stick (Admin → Records / Data → Export), for example for payroll.

  10. Test it

    Test with an enrolled person before you leave the site.

Quick setup facts

  • Face terminals (SIL-FRTEMP, SIL-ACCESSTEMP): set up on the device screen. Long-press the screen (or Menu) for the admin menu. Create the admin password the first time.
  • Network: RJ45 10/100. DHCP or a fixed address in Admin → Network.
  • Door wiring: lock relay (NO / COM / NC), exit button, door contact, and Wiegand 26/34 out to an access controller.
  • Turnstile (SIL-TURNSTILE3ARMSS): opens from a dry contact / relay signal (terminal, card reader or button).
  • Power: 12V DC adapter (terminals). Turnstile: mains power by an electrician.

Words to know

  • Access control: Lets only the right people through a door or gate.
  • Relay: An electric switch inside the device that unlocks the door lock.
  • IP address: The device's address on your network, like a house number (for example 192.168.1.88).
  • Enrolment: Adding a person's face or card to the device.

What's in the box

  • The device
  • Power supply or cable set (as listed)
  • Mounting hardware
  • Quick start card

Care

  • Clean the lens and screen with a soft, dry cloth.
  • Back up users to a USB stick from time to time.

Common questions

Something is wrong

See Fix Silarius access control.

Still stuck? We'll do it with you, free.

Silarius customers can get free remote help: sign in, click one button, and a Silarius technician joins your computer.