Fix cables, extenders, SFP modules and audio
No link light, no video through an extender, lines in the picture, no fiber link or no sound.
Find what you see below and try the checks in order.
No link light on the port
Try these in order:
- Test the cable with a cable tester. All 8 lights must come on.
- Re-crimp both plugs in the T568B order (how).
- Try a short patch cable to rule out the long one.
- Keep each run under 328 ft (100 m).
No video through the extender or coax box
Try these in order:
- Check IN and OUT are not swapped.
- Twist BNC plugs until they lock.
- Check the recorder-side unit has its power adapter (POC, EOC, C2HD).
- PoE extender: it needs PoE from the switch or NVR.
Lines, noise or rolling bars in the picture
Try these in order:
- Use solid-copper RG59 or RG6 coax.
- Keep coax away from mains power wires.
No fiber link on an SFP module
Try these in order:
- Both ends must be the same type and speed (single-mode 1310 nm).
- Swap the two fibers at one end.
- Clean the fiber plugs with a cleaning pen.
- On a managed switch, set the SFP port to 1000M full duplex.
No sound from the microphone
Try these in order:
- Check its 12V power and the wiring.
- Turn on audio for that channel, with stream type Video & Audio.
No picture on the TV over HDMI
Try these in order:
- Pick the right HDMI input on the TV. Try another cable. Restart the recorder with the TV on.
Still stuck?
Still not working? Ask for free remote setup help. A Silarius technician can look at it with you. Silarius hardware has a 3-year warranty (hard drives 5 years, solar products excluded). See the warranty.
Still stuck? We'll do it with you, free.
Silarius customers can get free remote help: sign in, click one button, and a Silarius technician joins your computer.